HemaPrompt FG is a widely used diagnostic test for detecting occult blood in stool and gastric samples. To ensure test accuracy, the internal control must function correctly.
If Hema FG control doesn’t turn blue, it indicates an invalid test, which means results cannot be trusted.
Understanding why this happens and how to address the issue is crucial for laboratory accuracy and reliable patient diagnostics.
Understanding the Internal Controls in HemaPrompt FG
HemaPrompt FG includes built-in internal controls to validate the test. The positive control should turn blue after activating the developer. If this does not occur, the test is invalid.
Key Control Components:
Control Type | Expected Result | Purpose |
Positive Control | Blue plus sign (+) | Confirms test functionality |
Negative Control | White background | Ensures no false positives |
A properly functioning internal control confirms that the test has been stored, handled, and performed correctly. If the positive control does not turn blue, the test results cannot be reported.
Why Does Hema FG Control Not Turn Blue?
Several factors can cause HemaPrompt FG to malfunction, leading to an invalid result. Below are the primary reasons why the positive control fails to turn blue:
1. Expired or Deteriorated Test Cards
Over time, test cards degrade, especially if they are exposed to improper storage conditions. Always check the expiration date before use and ensure test kits are stored in a dry, cool environment.
2. Incorrect Test Procedure
Proper technique is essential for test accuracy. Ensure that:
- The sample is applied correctly without excess spreading.
- The developer is activated by fully pulling the silver tab.
- The test card is not disturbed during development.
3. Environmental Factors
Exposure to heat, humidity, or volatile chemicals can compromise the integrity of the test. Store test kits in their original packaging away from direct sunlight, extreme temperatures, and strong-smelling chemicals.
4. Dry or Ineffective Developer Pad
If the developer pad is dry or defective, the chemical reaction needed to turn the control blue will not occur. Look for discoloration or signs of dryness and discard any compromised test cards.
How to Troubleshoot If Hema FG Control Doesn’t Turn Blue
When the internal control fails, follow these steps to identify and correct the issue:
Step 1: Check Expiration Date & Storage Conditions
Ensure that the test kit is within its valid period and stored according to manufacturer guidelines. Discard expired or improperly stored kits.
Step 2: Repeat the Test
Perform the test again with a fresh test card. If the issue persists, move to the next troubleshooting step.
Step 3: Verify Proper Test Technique
Review the procedure to ensure all steps were followed correctly. Make sure the developer tab was pulled fully, and the sample was applied properly.
Step 4: Assess Environmental Conditions
Ensure the test was performed in a controlled environment, free from excessive humidity, heat, or chemical exposure.
Step 5: Contact the Manufacturer
If all troubleshooting steps fail, consult the manufacturer for further guidance and possible product replacement.
Preventive Measures to Ensure Accurate Results
To avoid errors and maintain test reliability, follow these best practices:
1. Routine Quality Control Checks
Regularly inspect test kits for integrity, expiration dates, and proper storage conditions.
2. Staff Training & Competency Testing
Ensure all personnel performing the test are properly trained to follow the correct procedures.
3. Proper Documentation & Record Keeping
Maintain records of test batch numbers, storage conditions, and any issues encountered to track and prevent recurring problems.
Conclusion
If Hema FG control doesn’t turn blue, it signals an invalid test, making it crucial to identify the cause and take corrective action. Proper test handling, storage, and execution are key to ensuring accurate and reliable results. By following best practices, you can minimize errors and improve diagnostic accuracy, ultimately benefiting patient care.
For consistent test performance, always adhere to manufacturer guidelines and maintain rigorous quality control procedures.